Nvmed: Add support for command & feature lockdown log page Added implementation for the new admin log page command to pull the command and feature lockdown log page. There were also changes made to support this change to the libnvme repo as a patch and those were put up for review separately This is to support E1.S SSD left shift development Tested: Successfully tested the new admin log page command on a local machine. Redfish URI dump - https://paste.googleplex.com/4664890681851904 Google-Bug-Id: 439949469 Change-Id: I0288788b9f85e182138e127e9348da32e979a26f Signed-off-by: Agrim Bharat <agrimbharat@google.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access
A typical dbus-sensors object support the following dbus interfaces:
Path /xyz/openbmc_project/sensors/<type>/<sensor_name>
Interfaces xyz.openbmc_project.Sensor.Value
xyz.openbmc_project.Sensor.Threshold.Critical
xyz.openbmc_project.Sensor.Threshold.Warning
xyz.openbmc_project.State.Decorator.Availability
xyz.openbmc_project.State.Decorator.OperationalStatus
xyz.openbmc_project.Association.Definitions
Sensor interfaces collection are described here.
Consumer examples of these interfaces are Redfish, Phosphor-Pid-Control, IPMI SDR.
dbus-sensor daemons are reactors that dynamically create and update sensors configuration when system configuration gets updated.
Using asio timers and async calls, dbus-sensor daemons read sensor values and check thresholds periodically. PropertiesChanged signals will be broadcasted for other services to consume when value or threshold status change. OperationStatus is set to false if the sensor is determined to be faulty.
A simple sensor example can be found here.
Sensor devices are described using Exposes records in configuration file. Name and Type fields are required. Different sensor types have different fields. Refer to entity manager schema for complete list.