nvmed: Expose LockdownMetric dynamically in static store Expose the NVMe Command and Feature Lockdown Metric (Log Page 0x14) dynamically based on the controller's supported log page list. Map standard NVME_LOG_LID_CMD_AND_FEAT_LOCKDOWN to LockdownMetric in logpageIdentifier. Register and instantiate LockdownMetric in initializeMetricStore only if Log Page 0x14 is reported as supported by the controller. Google-Bug-Id: 439949534 Tested: https://paste.googleplex.com/5125313488093184 Change-Id: I90646afa093d208185d9220833a154b372e3dfbd Signed-off-by: Agrim Bharat <agrimbharat@google.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access
A typical dbus-sensors object support the following dbus interfaces:
Path /xyz/openbmc_project/sensors/<type>/<sensor_name>
Interfaces xyz.openbmc_project.Sensor.Value
xyz.openbmc_project.Sensor.Threshold.Critical
xyz.openbmc_project.Sensor.Threshold.Warning
xyz.openbmc_project.State.Decorator.Availability
xyz.openbmc_project.State.Decorator.OperationalStatus
xyz.openbmc_project.Association.Definitions
Sensor interfaces collection are described here.
Consumer examples of these interfaces are Redfish, Phosphor-Pid-Control, IPMI SDR.
dbus-sensor daemons are reactors that dynamically create and update sensors configuration when system configuration gets updated.
Using asio timers and async calls, dbus-sensor daemons read sensor values and check thresholds periodically. PropertiesChanged signals will be broadcasted for other services to consume when value or threshold status change. OperationStatus is set to false if the sensor is determined to be faulty.
A simple sensor example can be found here.
Sensor devices are described using Exposes records in configuration file. Name and Type fields are required. Different sensor types have different fields. Refer to entity manager schema for complete list.