nvmed: do not add unsupported features to featureCollection on capability query error When querying feature capabilities (SEL=011b) during feature discovery, if the drive returns an error (such as Invalid Field in Command 0x02), do not add the feature to featureCollection. Advertising unsupported features causes Redfish and busctl queries to attempt unsupported NVMe commands, resulting in Service Unavailable and 500 Internal Error. Tested: Ran unit tests and verified on target hardware. Google-Bug-Id: 544517012 Change-Id: Ic699209edd0d819190fde0342459c4396a6a6964 Signed-off-by: Guangzong Chen <guangzong@google.com> TAG=agy CONV=322d2541-0ab6-49b1-8c8f-2aeba2f83067
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access
A typical dbus-sensors object support the following dbus interfaces:
Path /xyz/openbmc_project/sensors/<type>/<sensor_name>
Interfaces xyz.openbmc_project.Sensor.Value
xyz.openbmc_project.Sensor.Threshold.Critical
xyz.openbmc_project.Sensor.Threshold.Warning
xyz.openbmc_project.State.Decorator.Availability
xyz.openbmc_project.State.Decorator.OperationalStatus
xyz.openbmc_project.Association.Definitions
Sensor interfaces collection are described here.
Consumer examples of these interfaces are Redfish, Phosphor-Pid-Control, IPMI SDR.
dbus-sensor daemons are reactors that dynamically create and update sensors configuration when system configuration gets updated.
Using asio timers and async calls, dbus-sensor daemons read sensor values and check thresholds periodically. PropertiesChanged signals will be broadcasted for other services to consume when value or threshold status change. OperationStatus is set to false if the sensor is determined to be faulty.
A simple sensor example can be found here.
Sensor devices are described using Exposes records in configuration file. Name and Type fields are required. Different sensor types have different fields. Refer to entity manager schema for complete list.