NVMeDevice: Integrate subsystem startup Currently the associated NVMeSubsystem instance is stopped via NVMeDevice::stop() to maintain encapsulation. To mirror stop(), and given the subsystem also needs to be started in both the basic management command and MI paths, integrate the call to NVMeSubsystem::start() into NVMeDevice::start(). Note that NVMeDevice::start() is only invoked after instantiation of its object, in the same manner as NVMeSubsystem, and so is only ever invoked once. MCTP endpoint recovery calls back through the private NVMeDevice::setup() method, which is separate to (but invoked from) NVMeDevice::start(). Change-Id: Ie29782de1e0dd2581c59a9fdddca3942d52b2e77 Signed-off-by: Andrew Jeffery <andrew@codeconstruct.com.au>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access
A typical dbus-sensors object support the following dbus interfaces:
Path /xyz/openbmc_project/sensors/<type>/<sensor_name>
Interfaces xyz.openbmc_project.Sensor.Value
xyz.openbmc_project.Sensor.Threshold.Critical
xyz.openbmc_project.Sensor.Threshold.Warning
xyz.openbmc_project.State.Decorator.Availability
xyz.openbmc_project.State.Decorator.OperationalStatus
xyz.openbmc_project.Association.Definitions
Sensor interfaces collection are described here.
Consumer examples of these interfaces are Redfish, Phosphor-Pid-Control, IPMI SDR.
dbus-sensor daemons are reactors that dynamically create and update sensors configuration when system configuration gets updated.
Using asio timers and async calls, dbus-sensor daemons read sensor values and check thresholds periodically. PropertiesChanged signals will be broadcasted for other services to consume when value or threshold status change. OperationStatus is set to false if the sensor is determined to be faulty.
A simple sensor example can be found here.
Sensor devices are described using Exposes records in configuration file. Name and Type fields are required. Different sensor types have different fields. Refer to entity manager schema for complete list.