mctp: accept an I3C address published as bytes The provisioned ID in an MCTPI3CTarget configuration is six bytes, and the interface definition [1] types Address as an array of bytes, which is also the form mctpd takes a physical address in. Entity manager publishes it as an array of uint64 today, but once its schema names the type as an array of bytes [2], Address arrives as one and is rejected here, leaving the endpoint unconfigured. Accept an array already in the element type as it is, alongside the array of uint64, so the reactor keeps working on either side of that change in entity manager. [1] https://gerrit.openbmc.org/c/openbmc/phosphor-dbus-interfaces/+/96008 [2] https://gerrit.openbmc.org/c/openbmc/entity-manager/+/97096 Tested: The new unit tests pass. On an nvl32-obmc machine, with this MCTPI3CTarget added to a board configuration: "Address": [7, 43, 0, 0, 0, 1], "Bus": 250, "Type": "MCTPI3CTarget" With [2], entity manager publishes Address as ay. Before this change mctpreactor rejects it: Cannot handle type std::vector<unsigned char> to vector<U> After this change it is accepted, and setup goes on until it looks for the I3C MCTP interface, which this machine does not have: No matching net device found for I3C bus 250 Without [2], Address is published as at and is accepted as before. The existing 23 USB MCTP endpoints are set up as before. Change-Id: Id7547e29c719d030cf04ba3412c2fbae15039b9f Signed-off-by: Ender Hsieh <andhsieh@nvidia.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access
A typical dbus-sensors object support the following dbus interfaces:
Path /xyz/openbmc_project/sensors/<type>/<sensor_name> Interfaces xyz.openbmc_project.Sensor.Value xyz.openbmc_project.Sensor.Threshold.Critical xyz.openbmc_project.Sensor.Threshold.Warning xyz.openbmc_project.State.Decorator.Availability xyz.openbmc_project.State.Decorator.OperationalStatus xyz.openbmc_project.Association.Definitions
Sensor interfaces collection are described in phosphor-dbus-interfaces.
Consumer examples of these interfaces are Redfish, Phosphor-Pid-Control, IPMI SDR.
dbus-sensor daemons are reactors that dynamically create and update sensors configuration when system configuration gets updated.
Using asio timers and async calls, dbus-sensor daemons read sensor values and check thresholds periodically. PropertiesChanged signals will be broadcasted for other services to consume when value or threshold status change. OperationStatus is set to false if the sensor is determined to be faulty.
A simple sensor example can be found in entity-manager examples.
Sensor devices are described using Exposes records in configuration file. Name and Type fields are required. Different sensor types have different fields. Refer to entity manager schema for complete list.
ADC sensors are sensors based on an Analog to Digital Converter. They are read via the Linux kernel Industrial I/O subsystem (IIO).
One of the more common use cases within OpenBMC is for reading these sensors from the ADC on the Aspeed ASTXX cards.
To utilize ADC sensors feature within OpenBMC you must first define and enable it within the kernel device tree.
When using a common OpenBMC device like the AST2600 you will find a “adc0” and “adc1” section in the aspeed-g6.dtsi file. These are disabled by default so in your system-specific dts you would enable and configure what you want with something like this:
iio-hwmon { compatible = "iio-hwmon"; io-channels = <&adc0 0>; ... } &adc0 { status = "okay"; ... }; &adc1 { status = "okay"; ... };
Note that this is not meant to be an exhaustive list on the nuances of configuring a device tree but really to point users in the general direction.
You will then create an entity-manager configuration file that is of type “ADC” A very simple example would like look this:
"Index": 0, "Name": "P12V", "PowerState": "Always", "ScaleFactor": 1.0, "Type": "ADC"
When your system is booted, a “in0_input” file will be created within the hwmon subsystem (/sys/class/hwmon/hwmonX). The adcsensor application will scan d-bus for any ADC entity-manager objects, look up their “Index” value, and try to match that with the hwmon inY_input files. When it finds a match it will create a d-bus sensor under the xyz.openbmc_project.ADCSensor service. The sensor will be periodically updated based on readings from the hwmon file.