entity-manager: Increasing the bus read timeout for FRU

The FRU for NVME M2 SSD went missing after chassis power cycle.
By increasing the I2C bus read timeout, allowing the service more time
to read the FRU for the device. Worst case measurement during 10 DC
Cycles is 6 seconds.

Upstream: <upstream 7329a22510f77ec49de3aebdcd975044d30e862a>
ref: https://gerrit.openbmc.org/c/openbmc/entity-manager/+/64716

Tested:
Set two machines to do dc cycle
machine 1 pass 119 power cycles
machine 2 pass 120 power cycles

Google-Bug-Id: 296187577
Change-Id: I44fd18b2ea8a469aa1d2d77e25951c83a4746690
Signed-off-by: Duke Du <duke.du@quanta.corp-partner.google.com>