oem-meta: santabarbara: update ASIC event logs
Update the Santabarbara ASIC event logs with the latest definitions
requested by the Meta ASIC team.
Test on Santabarbara platform
```
"103": {
"additional_data": {
"DEVICE": "/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/ubc1_ot_warning",
"FAILURE_DATA": "RAINBOW_UBC1_OT_WARNING - [02 03]",
"_CODE_FILE": "/usr/src/debug/pldm/1.0+git/oem/meta/libpldmresponder/file_io_type_event_log.cpp",
"_CODE_FUNC": "void pldm::responder::oem_meta::record::commit(const std::string&, pldm::responder::oem_meta::EventAssert, const std::string&) [with const char* TypeLabel = (& label); AssertType = sdbusplus::error::xyz::openbmc_project::state::Thermal::DeviceOverOperatingTemperatureFault; DeassertType = sdbusplus::event::xyz::openbmc_project::state::Thermal::DeviceOperatingNormalTemperature; std::string = std::__cxx11::basic_string<char>]",
"_CODE_LINE": "202",
"_PID": "1779"
},
"event_id": "",
"message": "xyz.openbmc_project.State.Thermal.DeviceOverOperatingTemperatureFault",
"redfish": {
"args": [
"/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/ubc1_ot_warning"
],
"id": "OpenBMC_StateThermal.DeviceOverOperatingTemperatureFault",
"message": "Device /xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/ubc1_ot_warning is significantly over safe operating temperature and may have been powered off."
},
"resolution": "",
"resolved": false,
"severity": "xyz.openbmc_project.Logging.Entry.Level.Critical",
"timestamp": "2026-07-29T07:33:38.563000000Z",
"updated_timestamp": "2026-07-29T07:33:38.563000000Z"
},
"104": {
"additional_data": {
"DEVICE": "/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/p0v85_medha1_vdd_ot_warning",
"FAILURE_DATA": "RAINBOW_P0V85_MEDHA1_VDD_OT_WARNING - [02 03]",
"_CODE_FILE": "/usr/src/debug/pldm/1.0+git/oem/meta/libpldmresponder/file_io_type_event_log.cpp",
"_CODE_FUNC": "void pldm::responder::oem_meta::record::commit(const std::string&, pldm::responder::oem_meta::EventAssert, const std::string&) [with const char* TypeLabel = (& label); AssertType = sdbusplus::error::xyz::openbmc_project::state::Thermal::DeviceOverOperatingTemperatureFault; DeassertType = sdbusplus::event::xyz::openbmc_project::state::Thermal::DeviceOperatingNormalTemperature; std::string = std::__cxx11::basic_string<char>]",
"_CODE_LINE": "202",
"_PID": "1779"
},
"event_id": "",
"message": "xyz.openbmc_project.State.Thermal.DeviceOverOperatingTemperatureFault",
"redfish": {
"args": [
"/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/p0v85_medha1_vdd_ot_warning"
],
"id": "OpenBMC_StateThermal.DeviceOverOperatingTemperatureFault",
"message": "Device /xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/p0v85_medha1_vdd_ot_warning is significantly over safe operating temperature and may have been powered off."
},
"resolution": "",
"resolved": false,
"severity": "xyz.openbmc_project.Logging.Entry.Level.Critical",
"timestamp": "2026-07-29T07:34:00.855000000Z",
"updated_timestamp": "2026-07-29T07:34:00.855000000Z"
},
"105": {
"additional_data": {
"DEVICE": "/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/p0v85_medha0_vdd_ot_warning",
"FAILURE_DATA": "RAINBOW_P0V85_MEDHA0_VDD_OT_WARNING - [02 03]",
"_CODE_FILE": "/usr/src/debug/pldm/1.0+git/oem/meta/libpldmresponder/file_io_type_event_log.cpp",
"_CODE_FUNC": "void pldm::responder::oem_meta::record::commit(const std::string&, pldm::responder::oem_meta::EventAssert, const std::string&) [with const char* TypeLabel = (& label); AssertType = sdbusplus::error::xyz::openbmc_project::state::Thermal::DeviceOverOperatingTemperatureFault; DeassertType = sdbusplus::event::xyz::openbmc_project::state::Thermal::DeviceOperatingNormalTemperature; std::string = std::__cxx11::basic_string<char>]",
"_CODE_LINE": "202",
"_PID": "1779"
},
"event_id": "",
"message": "xyz.openbmc_project.State.Thermal.DeviceOverOperatingTemperatureFault",
"redfish": {
"args": [
"/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/p0v85_medha0_vdd_ot_warning"
],
"id": "OpenBMC_StateThermal.DeviceOverOperatingTemperatureFault",
"message": "Device /xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/p0v85_medha0_vdd_ot_warning is significantly over safe operating temperature and may have been powered off."
},
"resolution": "",
"resolved": false,
"severity": "xyz.openbmc_project.Logging.Entry.Level.Critical",
"timestamp": "2026-07-29T07:34:07.056000000Z",
"updated_timestamp": "2026-07-29T07:34:07.056000000Z"
}
"106": {
"additional_data": {
"DEVICE": "/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/ubc2_ot_warning",
"FAILURE_DATA": "RAINBOW_UBC2_OT_WARNING - [02 03]",
"_CODE_FILE": "/usr/src/debug/pldm/1.0+git/oem/meta/libpldmresponder/file_io_type_event_log.cpp",
"_CODE_FUNC": "void pldm::responder::oem_meta::record::commit(const std::string&, pldm::responder::oem_meta::EventAssert, const std::string&) [with const char* TypeLabel = (& label); AssertType = sdbusplus::error::xyz::openbmc_project::state::Thermal::DeviceOverOperatingTemperatureFault; DeassertType = sdbusplus::event::xyz::openbmc_project::state::Thermal::DeviceOperatingNormalTemperature; std::string = std::__cxx11::basic_string<char>]",
"_CODE_LINE": "202",
"_PID": "1779"
},
"event_id": "",
"message": "xyz.openbmc_project.State.Thermal.DeviceOverOperatingTemperatureFault",
"redfish": {
"args": [
"/xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/ubc2_ot_warning"
],
"id": "OpenBMC_StateThermal.DeviceOverOperatingTemperatureFault",
"message": "Device /xyz/openbmc_project/inventory/system/board/Santa_Barbara_Rainbow_module_2/ubc2_ot_warning is significantly over safe operating temperature and may have been powered off."
},
"resolution": "",
"resolved": false,
"severity": "xyz.openbmc_project.Logging.Entry.Level.Critical",
"timestamp": "2026-07-29T07:37:53.564000000Z",
"updated_timestamp": "2026-07-29T07:37:53.564000000Z"
}
}
```
Change-Id: I22b2354a4ffc3327cb1c58a995f54acb38bbba11
Signed-off-by: Henry Wu <Henry_Wu@quantatw.com>
PLDM (Platform Level Data Model) is a key component of the OpenBMC project, providing a standardized data model and message formats for various platform management functionalities. It defines a method to manage, monitor, and control the firmware and hardware of a system.
The OpenBMC PLDM project aims to implement the specifications defined by the Distributed Management Task Force (DMTF), allowing for interoperable management interfaces across different hardware and firmware components.
To build and run PLDM, you need the following dependencies:
MesonNinjaAlternatively, source an OpenBMC ARM/x86 SDK.
To build the PLDM project, follow these steps:
meson setup build && meson compile -C build
The simplest way of running the tests is as described by the meson man page:
meson test -C build
Alternatively, tests can be run in the OpenBMC CI docker container using these steps.
pldm daemon accepts a command line argument --verbose or --v or -v to enable the daemon to run in verbose mode. It can be done via adding this option to the environment file that pldm service consumes.
echo 'PLDMD_ARGS="--verbose"' > /etc/default/pldmd systemctl restart pldmd
rm /etc/default/pldmd systemctl restart pldmd
For complete documentation on the functionality and usage of this repository, please refer to the docs folder.