|  | What:		/sys/bus/iio/devices/iio:deviceX/ac_excitation_en | 
|  | KernelVersion: | 
|  | Contact:	linux-iio@vger.kernel.org | 
|  | Description: | 
|  | This attribute, if available, is used to enable the AC | 
|  | excitation mode found on some converters. In ac excitation mode, | 
|  | the polarity of the excitation voltage is reversed on | 
|  | alternate cycles, to eliminate DC errors. | 
|  |  | 
|  | What:		/sys/bus/iio/devices/iio:deviceX/bridge_switch_en | 
|  | KernelVersion: | 
|  | Contact:	linux-iio@vger.kernel.org | 
|  | Description: | 
|  | This attribute, if available, is used to close or open the | 
|  | bridge power down switch found on some converters. | 
|  | In bridge applications, such as strain gauges and load cells, | 
|  | the bridge itself consumes the majority of the current in the | 
|  | system. To minimize the current consumption of the system, | 
|  | the bridge can be disconnected (when it is not being used | 
|  | using the bridge_switch_en attribute. | 
|  |  | 
|  | What:		/sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration | 
|  | KernelVersion: | 
|  | Contact:	linux-iio@vger.kernel.org | 
|  | Description: | 
|  | Initiates the system calibration procedure. This is done on a | 
|  | single channel at a time. Write '1' to start the calibration. | 
|  |  | 
|  | What:		/sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw | 
|  | KernelVersion: | 
|  | Contact:	linux-iio@vger.kernel.org | 
|  | Description: | 
|  | Measure voltage from AIN2 pin connected to AIN(+) | 
|  | and AIN(-) shorted. | 
|  |  | 
|  | What:		/sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available | 
|  | KernelVersion: | 
|  | Contact:	linux-iio@vger.kernel.org | 
|  | Description: | 
|  | Reading returns a list with the possible calibration modes. | 
|  | There are two available options: | 
|  | "zero_scale" - calibrate to zero scale | 
|  | "full_scale" - calibrate to full scale | 
|  |  | 
|  | What:		/sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode | 
|  | KernelVersion: | 
|  | Contact:	linux-iio@vger.kernel.org | 
|  | Description: | 
|  | Sets up the calibration mode used in the system calibration | 
|  | procedure. Reading returns the current calibration mode. | 
|  | Writing sets the system calibration mode. |