|  | .. SPDX-License-Identifier: GPL-2.0 | 
|  |  | 
|  | ============ | 
|  | NET_FAILOVER | 
|  | ============ | 
|  |  | 
|  | Overview | 
|  | ======== | 
|  |  | 
|  | The net_failover driver provides an automated failover mechanism via APIs | 
|  | to create and destroy a failover master netdev and mananges a primary and | 
|  | standby slave netdevs that get registered via the generic failover | 
|  | infrastructrure. | 
|  |  | 
|  | The failover netdev acts a master device and controls 2 slave devices. The | 
|  | original paravirtual interface is registered as 'standby' slave netdev and | 
|  | a passthru/vf device with the same MAC gets registered as 'primary' slave | 
|  | netdev. Both 'standby' and 'failover' netdevs are associated with the same | 
|  | 'pci' device. The user accesses the network interface via 'failover' netdev. | 
|  | The 'failover' netdev chooses 'primary' netdev as default for transmits when | 
|  | it is available with link up and running. | 
|  |  | 
|  | This can be used by paravirtual drivers to enable an alternate low latency | 
|  | datapath. It also enables hypervisor controlled live migration of a VM with | 
|  | direct attached VF by failing over to the paravirtual datapath when the VF | 
|  | is unplugged. | 
|  |  | 
|  | virtio-net accelerated datapath: STANDBY mode | 
|  | ============================================= | 
|  |  | 
|  | net_failover enables hypervisor controlled accelerated datapath to virtio-net | 
|  | enabled VMs in a transparent manner with no/minimal guest userspace chanages. | 
|  |  | 
|  | To support this, the hypervisor needs to enable VIRTIO_NET_F_STANDBY | 
|  | feature on the virtio-net interface and assign the same MAC address to both | 
|  | virtio-net and VF interfaces. | 
|  |  | 
|  | Here is an example XML snippet that shows such configuration. | 
|  | :: | 
|  |  | 
|  | <interface type='network'> | 
|  | <mac address='52:54:00:00:12:53'/> | 
|  | <source network='enp66s0f0_br'/> | 
|  | <target dev='tap01'/> | 
|  | <model type='virtio'/> | 
|  | <driver name='vhost' queues='4'/> | 
|  | <link state='down'/> | 
|  | <address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/> | 
|  | </interface> | 
|  | <interface type='hostdev' managed='yes'> | 
|  | <mac address='52:54:00:00:12:53'/> | 
|  | <source> | 
|  | <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/> | 
|  | </source> | 
|  | <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/> | 
|  | </interface> | 
|  |  | 
|  | Booting a VM with the above configuration will result in the following 3 | 
|  | netdevs created in the VM. | 
|  | :: | 
|  |  | 
|  | 4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000 | 
|  | link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff | 
|  | inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10 | 
|  | valid_lft 42482sec preferred_lft 42482sec | 
|  | inet6 fe80::97d8:db2:8c10:b6d6/64 scope link | 
|  | valid_lft forever preferred_lft forever | 
|  | 5: ens10nsby: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel master ens10 state UP group default qlen 1000 | 
|  | link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff | 
|  | 7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000 | 
|  | link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff | 
|  |  | 
|  | ens10 is the 'failover' master netdev, ens10nsby and ens11 are the slave | 
|  | 'standby' and 'primary' netdevs respectively. | 
|  |  | 
|  | Live Migration of a VM with SR-IOV VF & virtio-net in STANDBY mode | 
|  | ================================================================== | 
|  |  | 
|  | net_failover also enables hypervisor controlled live migration to be supported | 
|  | with VMs that have direct attached SR-IOV VF devices by automatic failover to | 
|  | the paravirtual datapath when the VF is unplugged. | 
|  |  | 
|  | Here is a sample script that shows the steps to initiate live migration on | 
|  | the source hypervisor. | 
|  | :: | 
|  |  | 
|  | # cat vf_xml | 
|  | <interface type='hostdev' managed='yes'> | 
|  | <mac address='52:54:00:00:12:53'/> | 
|  | <source> | 
|  | <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/> | 
|  | </source> | 
|  | <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/> | 
|  | </interface> | 
|  |  | 
|  | # Source Hypervisor | 
|  | #!/bin/bash | 
|  |  | 
|  | DOMAIN=fedora27-tap01 | 
|  | PF=enp66s0f0 | 
|  | VF_NUM=5 | 
|  | TAP_IF=tap01 | 
|  | VF_XML= | 
|  |  | 
|  | MAC=52:54:00:00:12:53 | 
|  | ZERO_MAC=00:00:00:00:00:00 | 
|  |  | 
|  | virsh domif-setlink $DOMAIN $TAP_IF up | 
|  | bridge fdb del $MAC dev $PF master | 
|  | virsh detach-device $DOMAIN $VF_XML | 
|  | ip link set $PF vf $VF_NUM mac $ZERO_MAC | 
|  |  | 
|  | virsh migrate --live $DOMAIN qemu+ssh://$REMOTE_HOST/system | 
|  |  | 
|  | # Destination Hypervisor | 
|  | #!/bin/bash | 
|  |  | 
|  | virsh attach-device $DOMAIN $VF_XML | 
|  | virsh domif-setlink $DOMAIN $TAP_IF down |