|  | // SPDX-License-Identifier: GPL-2.0+ | 
|  | /* | 
|  | * Functions to access SY3686A power management chip temperature | 
|  | * | 
|  | * Copyright (C) 2021 reMarkable AS - http://www.remarkable.com/ | 
|  | * | 
|  | * Authors: Lars Ivar Miljeteig <lars.ivar.miljeteig@remarkable.com> | 
|  | *          Alistair Francis <alistair@alistair23.me> | 
|  | */ | 
|  |  | 
|  | #include <linux/err.h> | 
|  | #include <linux/hwmon.h> | 
|  | #include <linux/init.h> | 
|  | #include <linux/module.h> | 
|  | #include <linux/platform_device.h> | 
|  | #include <linux/regmap.h> | 
|  | #include <linux/regulator/machine.h> | 
|  |  | 
|  | #include <linux/mfd/sy7636a.h> | 
|  |  | 
|  | static int sy7636a_read(struct device *dev, enum hwmon_sensor_types type, | 
|  | u32 attr, int channel, long *temp) | 
|  | { | 
|  | struct regmap *regmap = dev_get_drvdata(dev); | 
|  | int ret, reg_val; | 
|  |  | 
|  | ret = regmap_read(regmap, | 
|  | SY7636A_REG_TERMISTOR_READOUT, ®_val); | 
|  | if (ret) | 
|  | return ret; | 
|  |  | 
|  | *temp = reg_val * 1000; | 
|  |  | 
|  | return 0; | 
|  | } | 
|  |  | 
|  | static umode_t sy7636a_is_visible(const void *data, | 
|  | enum hwmon_sensor_types type, | 
|  | u32 attr, int channel) | 
|  | { | 
|  | if (type != hwmon_temp) | 
|  | return 0; | 
|  |  | 
|  | if (attr != hwmon_temp_input) | 
|  | return 0; | 
|  |  | 
|  | return 0444; | 
|  | } | 
|  |  | 
|  | static const struct hwmon_ops sy7636a_hwmon_ops = { | 
|  | .is_visible = sy7636a_is_visible, | 
|  | .read = sy7636a_read, | 
|  | }; | 
|  |  | 
|  | static const struct hwmon_channel_info * const sy7636a_info[] = { | 
|  | HWMON_CHANNEL_INFO(chip, HWMON_C_REGISTER_TZ), | 
|  | HWMON_CHANNEL_INFO(temp, HWMON_T_INPUT), | 
|  | NULL | 
|  | }; | 
|  |  | 
|  | static const struct hwmon_chip_info sy7636a_chip_info = { | 
|  | .ops = &sy7636a_hwmon_ops, | 
|  | .info = sy7636a_info, | 
|  | }; | 
|  |  | 
|  | static int sy7636a_sensor_probe(struct platform_device *pdev) | 
|  | { | 
|  | struct regmap *regmap = dev_get_regmap(pdev->dev.parent, NULL); | 
|  | struct regulator *regulator; | 
|  | struct device *hwmon_dev; | 
|  | int err; | 
|  |  | 
|  | if (!regmap) | 
|  | return -EPROBE_DEFER; | 
|  |  | 
|  | regulator = devm_regulator_get(&pdev->dev, "vcom"); | 
|  | if (IS_ERR(regulator)) | 
|  | return PTR_ERR(regulator); | 
|  |  | 
|  | err = regulator_enable(regulator); | 
|  | if (err) | 
|  | return err; | 
|  |  | 
|  | hwmon_dev = devm_hwmon_device_register_with_info(&pdev->dev, | 
|  | "sy7636a_temperature", regmap, | 
|  | &sy7636a_chip_info, NULL); | 
|  |  | 
|  | if (IS_ERR(hwmon_dev)) { | 
|  | err = PTR_ERR(hwmon_dev); | 
|  | dev_err(&pdev->dev, "Unable to register hwmon device, returned %d\n", err); | 
|  | return err; | 
|  | } | 
|  |  | 
|  | return 0; | 
|  | } | 
|  |  | 
|  | static struct platform_driver sy7636a_sensor_driver = { | 
|  | .probe = sy7636a_sensor_probe, | 
|  | .driver = { | 
|  | .name = "sy7636a-temperature", | 
|  | }, | 
|  | }; | 
|  | module_platform_driver(sy7636a_sensor_driver); | 
|  |  | 
|  | MODULE_DESCRIPTION("SY7636A sensor driver"); | 
|  | MODULE_LICENSE("GPL"); |