 | Charger Manager | 
 | =============== | 
 |  | 
 | 	(C) 2011 MyungJoo Ham <myungjoo.ham@samsung.com>, GPL | 
 |  | 
 | Charger Manager provides in-kernel battery charger management that | 
 | requires temperature monitoring during suspend-to-RAM state | 
 | and where each battery may have multiple chargers attached and the userland | 
 | wants to look at the aggregated information of the multiple chargers. | 
 |  | 
 | Charger Manager is a platform_driver with power-supply-class entries. | 
 | An instance of Charger Manager (a platform-device created with Charger-Manager) | 
 | represents an independent battery with chargers. If there are multiple | 
 | batteries with their own chargers acting independently in a system, | 
 | the system may need multiple instances of Charger Manager. | 
 |  | 
 | 1. Introduction | 
 | =============== | 
 |  | 
 | Charger Manager supports the following: | 
 |  | 
 | * Support for multiple chargers (e.g., a device with USB, AC, and solar panels) | 
 | 	A system may have multiple chargers (or power sources) and some of | 
 | 	they may be activated at the same time. Each charger may have its | 
 | 	own power-supply-class and each power-supply-class can provide | 
 | 	different information about the battery status. This framework | 
 | 	aggregates charger-related information from multiple sources and | 
 | 	shows combined information as a single power-supply-class. | 
 |  | 
 | * Support for in suspend-to-RAM polling (with suspend_again callback) | 
 | 	While the battery is being charged and the system is in suspend-to-RAM, | 
 | 	we may need to monitor the battery health by looking at the ambient or | 
 | 	battery temperature. We can accomplish this by waking up the system | 
 | 	periodically. However, such a method wakes up devices unnecessarily for | 
 | 	monitoring the battery health and tasks, and user processes that are | 
 | 	supposed to be kept suspended. That, in turn, incurs unnecessary power | 
 | 	consumption and slow down charging process. Or even, such peak power | 
 | 	consumption can stop chargers in the middle of charging | 
 | 	(external power input < device power consumption), which not | 
 | 	only affects the charging time, but the lifespan of the battery. | 
 |  | 
 | 	Charger Manager provides a function "cm_suspend_again" that can be | 
 | 	used as suspend_again callback of platform_suspend_ops. If the platform | 
 | 	requires tasks other than cm_suspend_again, it may implement its own | 
 | 	suspend_again callback that calls cm_suspend_again in the middle. | 
 | 	Normally, the platform will need to resume and suspend some devices | 
 | 	that are used by Charger Manager. | 
 |  | 
 | * Support for premature full-battery event handling | 
 | 	If the battery voltage drops by "fullbatt_vchkdrop_uV" after | 
 | 	"fullbatt_vchkdrop_ms" from the full-battery event, the framework | 
 | 	restarts charging. This check is also performed while suspended by | 
 | 	setting wakeup time accordingly and using suspend_again. | 
 |  | 
 | * Support for uevent-notify | 
 | 	With the charger-related events, the device sends | 
 | 	notification to users with UEVENT. | 
 |  | 
 | 2. Global Charger-Manager Data related with suspend_again | 
 | ========================================================= | 
 | In order to setup Charger Manager with suspend-again feature | 
 | (in-suspend monitoring), the user should provide charger_global_desc | 
 | with setup_charger_manager(`struct charger_global_desc *`). | 
 | This charger_global_desc data for in-suspend monitoring is global | 
 | as the name suggests. Thus, the user needs to provide only once even | 
 | if there are multiple batteries. If there are multiple batteries, the | 
 | multiple instances of Charger Manager share the same charger_global_desc | 
 | and it will manage in-suspend monitoring for all instances of Charger Manager. | 
 |  | 
 | The user needs to provide all the three entries to `struct charger_global_desc` | 
 | properly in order to activate in-suspend monitoring: | 
 |  | 
 | `char *rtc_name;` | 
 | 	The name of rtc (e.g., "rtc0") used to wakeup the system from | 
 | 	suspend for Charger Manager. The alarm interrupt (AIE) of the rtc | 
 | 	should be able to wake up the system from suspend. Charger Manager | 
 | 	saves and restores the alarm value and use the previously-defined | 
 | 	alarm if it is going to go off earlier than Charger Manager so that | 
 | 	Charger Manager does not interfere with previously-defined alarms. | 
 |  | 
 | `bool (*rtc_only_wakeup)(void);` | 
 | 	This callback should let CM know whether | 
 | 	the wakeup-from-suspend is caused only by the alarm of "rtc" in the | 
 | 	same struct. If there is any other wakeup source triggered the | 
 | 	wakeup, it should return false. If the "rtc" is the only wakeup | 
 | 	reason, it should return true. | 
 |  | 
 | `bool assume_timer_stops_in_suspend;` | 
 | 	if true, Charger Manager assumes that | 
 | 	the timer (CM uses jiffies as timer) stops during suspend. Then, CM | 
 | 	assumes that the suspend-duration is same as the alarm length. | 
 |  | 
 |  | 
 | 3. How to setup suspend_again | 
 | ============================= | 
 | Charger Manager provides a function "extern bool cm_suspend_again(void)". | 
 | When cm_suspend_again is called, it monitors every battery. The suspend_ops | 
 | callback of the system's platform_suspend_ops can call cm_suspend_again | 
 | function to know whether Charger Manager wants to suspend again or not. | 
 | If there are no other devices or tasks that want to use suspend_again | 
 | feature, the platform_suspend_ops may directly refer to cm_suspend_again | 
 | for its suspend_again callback. | 
 |  | 
 | The cm_suspend_again() returns true (meaning "I want to suspend again") | 
 | if the system was woken up by Charger Manager and the polling | 
 | (in-suspend monitoring) results in "normal". | 
 |  | 
 | 4. Charger-Manager Data (struct charger_desc) | 
 | ============================================= | 
 | For each battery charged independently from other batteries (if a series of | 
 | batteries are charged by a single charger, they are counted as one independent | 
 | battery), an instance of Charger Manager is attached to it. The following | 
 |  | 
 | struct charger_desc elements: | 
 |  | 
 | `char *psy_name;` | 
 | 	The power-supply-class name of the battery. Default is | 
 | 	"battery" if psy_name is NULL. Users can access the psy entries | 
 | 	at "/sys/class/power_supply/[psy_name]/". | 
 |  | 
 | `enum polling_modes polling_mode;` | 
 | 	  CM_POLL_DISABLE: | 
 | 		do not poll this battery. | 
 | 	  CM_POLL_ALWAYS: | 
 | 		always poll this battery. | 
 | 	  CM_POLL_EXTERNAL_POWER_ONLY: | 
 | 		poll this battery if and only if an external power | 
 | 		source is attached. | 
 | 	  CM_POLL_CHARGING_ONLY: | 
 | 		poll this battery if and only if the battery is being charged. | 
 |  | 
 | `unsigned int fullbatt_vchkdrop_ms; / unsigned int fullbatt_vchkdrop_uV;` | 
 | 	If both have non-zero values, Charger Manager will check the | 
 | 	battery voltage drop fullbatt_vchkdrop_ms after the battery is fully | 
 | 	charged. If the voltage drop is over fullbatt_vchkdrop_uV, Charger | 
 | 	Manager will try to recharge the battery by disabling and enabling | 
 | 	chargers. Recharge with voltage drop condition only (without delay | 
 | 	condition) is needed to be implemented with hardware interrupts from | 
 | 	fuel gauges or charger devices/chips. | 
 |  | 
 | `unsigned int fullbatt_uV;` | 
 | 	If specified with a non-zero value, Charger Manager assumes | 
 | 	that the battery is full (capacity = 100) if the battery is not being | 
 | 	charged and the battery voltage is equal to or greater than | 
 | 	fullbatt_uV. | 
 |  | 
 | `unsigned int polling_interval_ms;` | 
 | 	Required polling interval in ms. Charger Manager will poll | 
 | 	this battery every polling_interval_ms or more frequently. | 
 |  | 
 | `enum data_source battery_present;` | 
 | 	CM_BATTERY_PRESENT: | 
 | 		assume that the battery exists. | 
 | 	CM_NO_BATTERY: | 
 | 		assume that the battery does not exists. | 
 | 	CM_FUEL_GAUGE: | 
 | 		get battery presence information from fuel gauge. | 
 | 	CM_CHARGER_STAT: | 
 | 		get battery presence from chargers. | 
 |  | 
 | `char **psy_charger_stat;` | 
 | 	An array ending with NULL that has power-supply-class names of | 
 | 	chargers. Each power-supply-class should provide "PRESENT" (if | 
 | 	battery_present is "CM_CHARGER_STAT"), "ONLINE" (shows whether an | 
 | 	external power source is attached or not), and "STATUS" (shows whether | 
 | 	the battery is {"FULL" or not FULL} or {"FULL", "Charging", | 
 | 	"Discharging", "NotCharging"}). | 
 |  | 
 | `int num_charger_regulators; / struct regulator_bulk_data *charger_regulators;` | 
 | 	Regulators representing the chargers in the form for | 
 | 	regulator framework's bulk functions. | 
 |  | 
 | `char *psy_fuel_gauge;` | 
 | 	Power-supply-class name of the fuel gauge. | 
 |  | 
 | `int (*temperature_out_of_range)(int *mC); / bool measure_battery_temp;` | 
 | 	This callback returns 0 if the temperature is safe for charging, | 
 | 	a positive number if it is too hot to charge, and a negative number | 
 | 	if it is too cold to charge. With the variable mC, the callback returns | 
 | 	the temperature in 1/1000 of centigrade. | 
 | 	The source of temperature can be battery or ambient one according to | 
 | 	the value of measure_battery_temp. | 
 |  | 
 |  | 
 | 5. Notify Charger-Manager of charger events: cm_notify_event() | 
 | ============================================================== | 
 | If there is an charger event is required to notify | 
 | Charger Manager, a charger device driver that triggers the event can call | 
 | cm_notify_event(psy, type, msg) to notify the corresponding Charger Manager. | 
 | In the function, psy is the charger driver's power_supply pointer, which is | 
 | associated with Charger-Manager. The parameter "type" | 
 | is the same as irq's type (enum cm_event_types). The event message "msg" is | 
 | optional and is effective only if the event type is "UNDESCRIBED" or "OTHERS". | 
 |  | 
 | 6. Other Considerations | 
 | ======================= | 
 |  | 
 | At the charger/battery-related events such as battery-pulled-out, | 
 | charger-pulled-out, charger-inserted, DCIN-over/under-voltage, charger-stopped, | 
 | and others critical to chargers, the system should be configured to wake up. | 
 | At least the following should wake up the system from a suspend: | 
 | a) charger-on/off b) external-power-in/out c) battery-in/out (while charging) | 
 |  | 
 | It is usually accomplished by configuring the PMIC as a wakeup source. |