| .. SPDX-License-Identifier: GPL-2.0+: | |
| .. index:: | |
| single: bind (command) | |
| bind command | |
| ============ | |
| Synopsis | |
| -------- | |
| :: | |
| bind <node path> <driver> | |
| bind <class> <seq> <driver> | |
| Description | |
| ----------- | |
| The bind command is used to bind a device to a driver. This makes the | |
| device available in U-Boot. | |
| While binding to a *node path* typically provides a working device | |
| binding by parent node and driver may lead to a device that is only | |
| partially initialized. | |
| node path | |
| path of the device's device-tree node | |
| class | |
| device class name | |
| seq | |
| sequence number of the parent device in the device class | |
| driver | |
| device driver name | |
| Example | |
| ------- | |
| Given a system with a real time clock device with device path */pl031@9010000* | |
| and using driver rtc-pl031 unbinding and binding of the device is demonstrated | |
| using the two alternative bind syntaxes. | |
| .. code-block:: | |
| => dm tree | |
| Class Seq Probed Driver Name | |
| ----------------------------------------------------------- | |
| root 0 [ + ] root_driver root_driver | |
| ... | |
| rtc 0 [ ] rtc-pl031 |-- pl031@9010000 | |
| ... | |
| => fdt addr $fdtcontroladdr | |
| Working FDT set to 7ed7fdb0 | |
| => fdt print | |
| / { | |
| interrupt-parent = <0x00008003>; | |
| model = "linux,dummy-virt"; | |
| #size-cells = <0x00000002>; | |
| #address-cells = <0x00000002>; | |
| compatible = "linux,dummy-virt"; | |
| ... | |
| pl031@9010000 { | |
| clock-names = "apb_pclk"; | |
| clocks = <0x00008000>; | |
| interrupts = <0x00000000 0x00000002 0x00000004>; | |
| reg = <0x00000000 0x09010000 0x00000000 0x00001000>; | |
| compatible = "arm,pl031", "arm,primecell"; | |
| }; | |
| ... | |
| } | |
| => unbind /pl031@9010000 | |
| => date | |
| Cannot find RTC: err=-19 | |
| => dm tree | |
| Class Seq Probed Driver Name | |
| ----------------------------------------------------------- | |
| root 0 [ + ] root_driver root_driver | |
| ... | |
| => bind /pl031@9010000 rtc-pl031 | |
| => dm tree | |
| Class Seq Probed Driver Name | |
| ----------------------------------------------------------- | |
| root 0 [ + ] root_driver root_driver | |
| ... | |
| rtc 0 [ ] rtc-pl031 |-- pl031@9010000 | |
| => date | |
| Date: 2023-06-22 (Thursday) Time: 15:14:51 | |
| => unbind rtc 0 rtc-pl031 | |
| => bind root 0 rtc-pl031 | |
| => date | |
| Date: 1980-08-19 (Tuesday) Time: 14:45:30 | |
| Obviously the device is not initialized correctly by the last bind command. | |
| Configuration | |
| ------------- | |